ISO 9001 Registered
About Us
Company
Leak Testing
Functional Testing
Assembly & Test
Med Device Testing
Applications Lab
Correlation Studies
Patents

Solutions
Medical
Industrial
Automotive
Leak Detectors
Mass Flow
Multi-Channel
Pressure Decay
Calibration
CALVAL
Medical Device Testers
FAQ
Calibration
Medical Device Test
Leak Testing
Assembly & Test
Contact Us
World Leader in Test Technology 1-847-679-3377
ISO 17025 Accredited
Patents


Infusion in the Operating Room
InterTech’s Patented Innovations for Leak Testing and Functional Testing
No other company invests as much time or engineering talent as InterTech to develop optimized custom solutions for leak testing, calibrating leaks and validating test technology, or functional testing. These R&D efforts have achieved unparalleled accuracy, speed, R&R, reliability and convenience in production line leak testing, flow testing, and functional testing.

InterTech's Patented Technology is the Underpinning of its ISO Accreditation for Highest Quality Standards

InterTech Development Company's ISO 9001-compliant manufacturer clientele can rely on InterTech’s ISO 17025 accreditation that its Calibration and Applications Laboratory meets the highest international standards for laboratory quality management.


For a no-cost and obligation-free consultation on how InterTech's patented technology can improve your leak test, functional test, or test and assembly call 847-679-3377 or click here.

Ask about InterTech's growing roster of patented innovations, including ---

CalVal - 2006 U.S. Patent 7,017,387

Electronic technology for self-calibration and automatic validation of leak testing with an accuracy of +/-2% of reading or 0.02 sccm (standard cubic centimeters per minute). CalVal does not require an operator and eliminates production delays for off-line mechanical calibration.

Advanced Mass Flow Sensor - 1992 U.S. Patent 5,161,410

Enhances the technology of dry air leak testing in factory environments by maintaining high measurement accuracy across a wider range of air pressures and temperatures, ambient temperatures, and random, short-duration disturbances in measured airflow.

Bias Flow Leak Testing - 1996 U.S. Patent 5,546,789

InterTech’s accuracy-sharpening technique couples downstream (bell jar) leak testing with a known preliminary airflow that confirms a leak-tight bell jar seal or sets a known leak reference. This allows true test part leakage to be measured more precisely in less time and is especially helpful in testing to low leak limits.

CalMaster - 1994 U.S. Patent 5,363,689

InterTech’s CalMaster obsoletes fragile, cumbersome soap film flowmeters and rotameters offering a rugged, user-adjustable, hand-held, electronic alternative that displays leak or flow rate continuously in digital read-out format with no user judgment or calculations needed.

Hydraulic Fluid/Dry Air Testing - 2001 U.S. Patent 6,279,383

InterTech’s technique for using air pressure rise to measure hydraulic fluid leakage significantly improves accuracy and repeatability by eliminating the variable effects of bulk modulus (fluid compressibility) that distorts conventional test methods relying on fluid pressure measurement.

Hydraulic/ Pneumatic Extending Clamp - 2002 U.S. Patent 6,442,550

InterTech’s design combines a compact body with a 2?reach and 1000 pounds of clamping force. These features shorten part-to-part cycle times by allowing ample clearance for loading parts into fixtures, and extending to apply the clamping force needed for effectively sealing the part.

Nuclear Magnetic Resonance Testing - 2003 U.S. Patent 6,626,027

Bypassing the limitations of helium mass spectrometry, InterTech’s newest technology for measuring leak rates as small as 10-11 sccs uses hyperpolarized helium-3 as a tracer gas detected by applying a magnetic field and radio frequency excitation, then measuring resonant electromagnetic frequency emitted by the He-3 nuclei. NMR testing provides shorter test cycle times, insensitivity to temperature variation or false detection of other environmental gases and impurities plus elimination of costly vacuum equipment and time-consuming maintenance associated with mass spectrometry.

THE IDC ADVANTAGE --- LEADING EDGE TECHNOLOGY, IN-DEPTH EXPERIENCE

Solutions News & Events 
Oxygen Delivery
Demand Oxygen Delivery System is calibrated and functionally tested at a rate of 18 parts per hour.

Catheter
Balloon diameter gauging and lumen leakage tests are performed at a rate of 310 pph.

8/11/2009 User Friendly Leak Detector
InterTech M1075y Leak Detector

9/11/2006 Engineering Talk
InterTech Electronic technology boosts leak-test
accuracy


7/11/2009 News RX
Leak Detector for Recession-Strapped Medical Device Manufacturers

Instrumentation 
What steps can we take to ensure uniform test results in globally distributed assembly and test operations?
A variety of “poka-yoke” methods may be used...

What is pressure decay leak detection?
In pressure decay leak detection...

ISO 17025 Accredited  |  Site Map

InterTech Development Company 7401 N. Linder Avenue, Skokie, IL 60077, USA T. 847.679.3377
InterTech Europe 19, rue Clement Michu F-69100 Villeurbanne,France (33)0437.434.116
Shanghai Technical Center 1F, Bldg #36, 458 North Fu Te Road Shanghai Waigaoqiao F.T.Z. 200131 P.R. China, (8621)58682809